LAS-XD TECICO Specialized Construction Laboratory
The LAS-XD TECICO Laboratory was established in 2026 to perform specialized construction testing for quality control during construction, supporting project owners and site supervision. The laboratory has announced its capability to perform specialized construction testing to the Hanoi Department of Construction in accordance with regulations.
I. General information
| Laboratory name | LAS-XD TECICO Specialized Construction Laboratory |
| Parent company | Transport Engineering Consultant International Joint Stock Company (TECICO) Enterprise code: 0105742545 |
| Establishment decision | No. 191/QĐ-HĐQT dated 26 June 2026 of the Board of Directors |
| Head of laboratory | Mr. Nguyen Dang Han – Master of Geotechnical Engineering |
| Capability announcement | No. 203/TECICO-TB dated 7 July 2026, submitted to the Hanoi Department of Construction |
| Address | No. 25, Lot 3, Lane 217 La Thanh Street, O Cho Dua Ward, Hanoi |
| Contact | Tel/Zalo: +84 362 630 380 – Email: contact@tecico.com |
II. Capabilities
- Personnel: 7 staff and testing technicians, including the head of laboratory, technical manager, quality manager and technicians.
- Machinery and equipment: 17 items according to the announced list, serving on-site testing.
- Test parameters: 18 parameters, including:
- Static axial compressive pile load test
- Cross-hole sonic logging of bored piles
- Bi-directional (O-Cell, self-balance) pile load test
- Core drilling to check pile toe sediment and concrete
- Compressive strength of soil-cement columns/piles
- Uplift (tension) pile load test
- Lateral pile load test
- Strain measurement in pile shaft concrete (sensors)
- High-strain dynamic pile testing (PDA)
- Plate load test for deformation modulus of soil
- Elastic modulus of road subgrade by large plate
- Field vane shear test (FVT)
- Standard penetration test (SPT)
- Pore water pressure, surface and deep settlement monitoring
- Borehole and in-situ permeability tests
- Thermal conductivity of soil
- Soil electrical resistivity
- Seismic testing (borehole, parallel, reflection, refraction)
III. Legal and capability documents
The documents below are official documents in Vietnamese.
| No. | Document | Number, date | File |
|---|---|---|---|
| 1 | Announcement of capability to perform specialized construction testing | 203/TECICO-TB, 07/07/2026 | View |
| 2 | Decision on establishment of the LAS-XD TECICO Laboratory | 191/QĐ-HĐQT, 26/06/2026 | View |
| 3 | Decision on appointment of the Head of Laboratory | 192/QĐ-TECICO, 26/06/2026 | View |
| 4 | List of laboratory staff and testing technicians (7 persons) | 203-1/TECICO-PTN, 07/07/2026 | View |
| 5 | List of degrees and training certificates | Updated 22/11/2026 | View |
| 6 | List of testing machinery, equipment and tools | 17 items | View |
| 7 | Enterprise registration information of TECICO | 15th amendment, 16/07/2026 | View |
| 8 | Confirmation of business lines of TECICO | 01/04/2026 | View |
| 9 | Technical standards applied to the 18 test parameters | Appendix 01 – announcement 203/TECICO-TB | View |
| 10 | List of technical documents, standards and testing procedures | — | Available on request |
| 11 | LAS-XD TECICO Laboratory capability profile 2026 | — | Available on request |
For the capability profile or a testing quotation, please contact: Tel/Zalo +84 362 630 380, email contact@tecico.com.


